Article, 2023

Performance of 8- vs 16 ECG-gated reconstructions in assessing myocardial function using Rubidium-82 myocardial perfusion imaging: Findings in a young, healthy population

Journal of Nuclear Cardiology, ISSN 1071-3581, Volume 30, 4, Pages 1406-1413, 10.1007/s12350-022-03193-0

Contributors

Lassen M.L. 0000-0002-3262-0146 (Corresponding author) [1] Wissenberg M. [2] Byrne C. 0000-0003-2705-3367 [1] Kjaer A. 0000-0002-2706-5547 [1] Hasbak P. [1]

Affiliations

  1. [1] Rigshospitalet
  2. [NORA names: Capital Region of Denmark; Hospital; Denmark; Europe, EU; Nordic; OECD];
  3. [2] Department of Cardiology
  4. [NORA names: Capital Region of Denmark; Hospital; Denmark; Europe, EU; Nordic; OECD]

Abstract

Background: Current imaging guidelines recommend using at least 16 ECG gates when performing MUGA and cardiac SPECT to assess left ventricular ejection fraction (LVEF). However, for Rubidium-82 (Rb) PET, 8 ECG-gated reconstructions have been a mainstay. This study investigated the implications of quantitative assessments when employing 16 gate, instead of 8 gate, reconstructions for Rb myocardial perfusion imaging (MPI). Methods: The study comprised 25 healthy volunteers (median age 23 years) who underwent repeat MPI sessions employing Rb PET/CT. We report LVEF, its reserve (stress LVEF – rest LVEF), and their repeatability measures (RMS method) obtained for 8- and 16 ECG-gated reconstructions. Results: Similar LVEF and LVEF reserve estimates were found for the 8- and 16-gated reconstructions ([%] LVEF (8/16 gates): rest = 61 ± 6/64 ± 6, stress = 68 ± 7/71 ± 6, LVEF reserve (8/16 gates): 8 ± 3/6 ± 4, and all P ≥ 0.13). Similar test–retest repeatability measures were observed for rest and stress LVEF and their reserves [LVEF (8/16 gates); Rest = 4.5/4.6 (P = 0.81), Stress = 3.5/3.2 (P = 0.33), LVEF reserve = 46.7/49.3 (P = 0.13)]. Conclusion: In healthy subjects, 8 and 16 ECG gates can be used interchangeably if only volumetric assessments are desired. However, if filling and emptying rates are of interest, a minimum of 16 ECG gates should be employed.

Keywords

Ejection fraction, PET, adenosine, cardiac imaging

Funders

  • Danish Health Authority
  • Novo Nordisk Fonden
  • European Research Council
  • Kræftens Bekæmpelse
  • Neye-Foundation
  • John and Birthe Meyer Foundation
  • Lundbeckfonden
  • Hørslev-Fonden
  • Horizon 2020 Framework Programme
  • Innovationsfonden
  • Research Council for Independent Research
  • Danmarks Grundforskningsfond
  • Arvid Nilssons Fond
  • Research Council of the Capital Region of Denmark

Data Provider: Elsevier